1136132 EDS-405A-MM-SC Êîììóòàòîð

Àðòèêóë 1136132
ÑÐÀÂÍÈÒÜ
 ÑÐÀÂÍÅÍÈÈ
/
Ìíîãî
- +
 êîðçèíó
ÄÎÁÀÂËÅÍÎ
Îïèñàíèå
Îòçûâû
Îïëàòà
Äîñòàâêà
Êîììóòàòîð 3 x 10/100BaseTX, 2 x 100BaseFX (ìíîãîìîäîâîå îïòîâîëîêíî) ñ áàçîâûìè ôóíêöèÿìè óïðàâëåíèÿ, ðàçúåì SC


  • Èíòåðôåéñ
  • Îáùåå êîëè÷åñòâî ïîðòîâ
    5
  • Óðîâåíü êîììóòàòîðà
    L2
  • Òèï ðàçúåìà äëÿ "âèòîé ïàðû"
    RJ45
  • Òåõíîëîãèè
  • Ñòàíäàðòû
    IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX, IEEE 802.3x for Flow Control, IEEE 802.1D-2004 for Spanning Tree Protocol, IEEE 802.1w for Rapid STP, IEEE 802.1p for Class of Service, IEEE 802.1Q for VLAN Tagging
  • Ïðîìûøëåííûå ïðîòîêîëû
    EtherNet/IP, Modbus/TCP
  • Ïðîòîêîëû óïðàâëåíèÿ
    IPv4/IPv6, SNMP v1/v2c/v3, LLDP, Port Mirror, RMON, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SMTP, RARP, Telnet, Syslog, SNMP Inform, Flow Control, Back Pressure Flow Control
  • Ïðîòîêîëû ôèëüòðàöèè
    802.1Q VLAN, Port-Based VLAN, GVRP, IGMP v1/v2, GMRP
  • Ïðîòîêîëû ðåçåðâèðîâàíèÿ
    STP, RSTP, Turbo Ring v1/v2, Turbo Chain
  • Ïðîòîêîëû ñèíõðîíèçàöèè âðåìåíè
    SNTP, NTP Server/Client
  • Óïðàâëåíèå ïîòîêàìè
    IEEE 802.3x flow control, back pressure flow control
  • Òàáëèöà MAC-àäðåñîâ
    2000
  • Ðàçìåð áóôåðà ïàêåòîâ
    1 Ìáèò
  • Ïîðòû Fast Ethernet 10/100 Ìáèò/ñ
  • Âèòàÿ ïàðà (ðàçúåì RJ45)
    3
  • Ïîðòû Fast Ethernet 100 Ìáèò/ñ
  • Ìíîãîìîäîâîå îïòîâîëîêíî (ðàçúåì SC)
    2
  • Õàðàêòåðèñòèêè îïòîâîëîêîííîãî èíòåðôåéñà Fast Ethernet
  • Òèï îïòîâîëîêîííîãî êàáåëÿ
    50/125 ìêì, 62.5/125 ìêì
  • Äàëüíîñòü ïåðåäà÷è ïî îïòîâîëîêíó
    äî 4 êì
  • Äëèíà âîëíû ïî îïòîâîëîêíó, íì
    1300
  • Ìîùíîñòü îïòè÷åñêîãî ïåðåäàò÷èêà, äÁì
    -20
  • ×óâñòâèòåëüíîñòü îïòè÷åñêîãî ïðèåìíèêà, äÁì
    -32
  • Äîïóñòèìûå ïîòåðè â êàíàëå ñâÿçè, äÁì
    12
  • Íàñûùåíèå ïðèåìíèêà, äÁì
    -6
  • Ðåëåéíûé âûâîä
  • Êîëè÷åñòâî êàíàëîâ ðåëåéíîãî âûâîäà
    1
  • Íàãðóçî÷íàÿ ñïîñîáíîñòü ðåëå
    1 À ïðè 24 Â ïîñò.
  • Ïîääåðæêà èíòåëëåêòóàëüíûõ ôóíêöèé
  • Àâòîìàòè÷åñêîå îïîâåùåíèå îá îáðûâå ýëåêòðîïèòàíèÿ
    Ïðè ïîìîùè ðåëå, ïî E-Mail, ïî SNMP
  • Àâòîìàòè÷åñêîå îïîâåùåíèå îá îáðûâå ñâÿçè ïî ïîðòó
    Ïðè ïîìîùè ðåëå, ïî E-Mail, ïî SNMP
  • Ñâåòîäèîäíûå èíäèêàòîðû
  • Ñâåòîäèîäíûå èíäèêàòîðû
    PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, 10/100M
  • Óïðàâëåíèå óñòðîéñòâîì
  • Èíòåðôåéñ óïðàâëåíèÿ
    Êîíñîëü RS-232
  • Ðàçúåì êîíñîëüíîãî ïîðòà RS-232
    RJ45
  • MIB-áàçû
    MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
  • DIP-ïåðåêëþ÷àòåëè
    Turbo Ring, Master, Coupler, Reserve
  • Òðåáîâàíèÿ ê ýëåêòðîïèòàíèþ
  • Ðàáî÷åå íàïðÿæåíèå
    12/24/48 Â ïîñò. (9.6 ~ 60 Â ïîñò.)
  • Ïîòðåáëåíèå òîêà
    0.26 À ïðè 24 Â
  • Âîçìîæíîñòü ïîäêëþ÷åíèÿ ðåçåðâíîãî èñòî÷íèêà ýëåêòðîïèòàíèÿ
    Åñòü
  • Ðàçúåì ýëåêòðîïèòàíèÿ
    Êëåììà
  • Çàùèòà îò íåâåðíîé ïîëÿðíîñòè
    Åñòü
  • Óñëîâèÿ ýêñïëóàòàöèè
  • Ðàáî÷àÿ òåìïåðàòóðà, °C
    0 ~ +60
  • Òåìïåðàòóðà õðàíåíèÿ, °C
    -40 ~ +85
  • Ðàáî÷àÿ âëàæíîñòü, %
    5 ~ 95
  • Çàùèòà
  • Çàùèòà îò ïûëè è âëàãè
    IP30
  • Çàùèòà ïî òîêó
    Åñòü
  • Êîíñòðóêòèâíûå ñâîéñòâà
  • Ìàòåðèàë êîðïóñà
    Ìåòàëë
  • Ðàçìåðû è âåñ
  • Ãàáàðèòíûå ðàçìåðû, ìì
    54 x 135 x 105
  • Âåñ íåòòî, êã
    0.65
  • Ìîíòàæ
  • Ìîíòàæ
    Íà DIN-ðåéêó
    Íàñòîëüíûé/íàñòåííûé (îïöèîíàëüíî)
  • Íàëè÷èå ìåæäóíàðîäíûõ ñåðòèôèêàòîâ
  • Áåçîïàñíîñòü
    CSA C22.2 No. 60950-1
    EN 60950-1
    UL508
    UL60950-1
  • Âçðûâîáåçîïàñíîñòü
    ATEX Zone 2 Ex nA nC IIC T4 Gc
    UL/cUL Class 1 Division 2
  • Ýëåêòðîìàãíèòíàÿ ñîâìåñòèìîñòü (EMI)
    CISPR 32
    FCC Part 15 Subpart B Class A
  • Ýëåêòðîìàãíèòíàÿ ñîâìåñòèìîñòü (EMS)
    IEC 61000-4-2 (ESD)
    IEC 61000-4-3 RS
    IEC 61000-4-4 (EFT)
    IEC 61000-4-5 Surge
    IEC 61000-4-6 CS
    IEC 61000-4-8
  • Ýëåêòðîìàãíèòíàÿ ñîâìåñòèìîñòü (EMC)
    EN 55032/24
  • Ïðèìåíåíèå â ìîðñêèõ ñèñòåìàõ
    DNV
    GL
  • Ïðèìåíåíèå íà òðàíñïîðòå
    NEMA TS2
  • Óäàðû
    IEC 60068-2-27
  • Ñâîáîäíîå ïàäåíèå
    IEC 60068-2-32
  • Âèáðàöèè
    IEC 60068-2-6
  • Ñðåäíåå âðåìÿ íàðàáîòêè íà îòêàç (MTBF), ÷àñîâ
    852421
  • Ãàðàíòèéíûé ñðîê
  • Ãàðàíòèéíûé ñðîê
    5 ëåò
  • Êîìïëåêò ïîñòàâêè
  • Êîìïëåêò ïîñòàâêè
    Çàãëóøêè äëÿ íåèñïîëüçóåìûõ ïîðòîâ
    Êîíñîëüíûé êàáåëü RJ45-íà-DB9
    Êðàòêîå ðóêîâîäñòâî ïîëüçîâàòåëÿ
    Óñòðîéñòâî
Âîçìîæíûå âàðèàíòû îïëàòû

Áåçíàëè÷íûé ðàñ÷åò — îñíîâíîé ñïîñîá îïëàòû çàêàçà äëÿ þðèäè÷åñêèõ è ôèçè÷åñêèõ ëèö. Ïîñëå îôîðìëåíèÿ âàìè çàêàçà è ïîëó÷åíèÿ ðåêâèçèòîâ, íà âàø ýëåêòðîííûé ïî÷òîâûé ÿùèê âûñûëàåòñÿ ñ÷¸ò íà îïëàòó, êîòîðûé ïîäëåæèò îïëàòå.*

Ìû ïðåäëàãàåì íàèáîëåå óäîáíûå äëÿ ïîêóïàòåëåé ôîðìû îïëàòû, ïî âûáîðó:
-ïðåäîïëàòà 100%;
-÷àñòè÷íàÿ ïðåäîïëàòà ñ îêîí÷àòåëüíîé îïëàòîé ïîñëå ïîëó÷åíèÿ îáîðóäîâàíèÿ;
-ðàññðî÷êà ïëàòåæà äëÿ ïîñòîÿííûõ êëèåíòîâ
Âàðèàíòû ïîëó÷åíèÿ çàêàçîâ

1) Ñàìîâûâîç. Ñõåìó ïðîåçäà ìîæíî ïîñìîòðåòü â ðàçäåëå ÊÎÍÒÀÊÒÛ.
2) Äîñòàâêà òîâàðà äî òðàíñïîðòíîé êîìïàíèè «Äåëîâûå Ëèíèè» äëÿ äàëüíåéøåé òðàíñïîðòèðîâêè â ëþáîé ðåãèîí Ðîññèè îñóùåñòâëÿåòñÿ áåñïëàòíî. Äàëåå ïî òàðèôàì òðàíñïîðòíîé êîìïàíèè «Äåëîâûå Ëèíèè».
Òàê æå ïî æåëàíèþ Êëèåíòà äîñòàâêà çàêàçà ìîæåò áûòü îñóùåñòâëåíà â ëþáóþ äðóãóþ òðàíñïîðòíóþ êîìïàíèþ, ñòîèìîñòü ýêñïåäèðîâàíèÿ ïî ã.Ìîñêâà èëè Ñàíêò-Ïåòåðáóðã â ýòîì ñëó÷àå ñîñòàâèò 1000 ðóáëåé.
3) Äîñòàâêà ìåëêîãàáàðèòíîãî òîâàðà ïî òåððèòîðèè Ðîññèè ìîæåò áûòü îñóùåñòâëåíà ñëóæáîé ýêñïðåñ-äîñòàâêè ÑÄÝÊ.  ýòîì ñëó÷àå ñòîèìîñòü äîñòàâêè ðàñ÷èòûâàåòñÿ èñõîäÿ èç òàðèôîâ äàííîé ñëóæáû.
4) Äîñòàâêà çàêàçà ïî Ìîñêâå â ïðåäåëàõ ÌÊÀÄ èëè â ïðåäåëàõ ÊÀÄ Ñàíêò-Ïåòåðáóðã ñîñòàâëÿåò 1000 ðóáëåé.


Ñêà÷àòü êàòàëîã Teknokol - ñèñòåìû íåñóùèõ ðû÷àãîâ è ïóëüòîâ óïðàâëåíèÿ