Êîìïàêòíûé êîììóòàòîð 4 x 10/100BaseTX, 1 x 100BaseFX (îäíîìîäîâîå îïòîâîëîêíî) â ìåòàëëè÷åñêîì êîðïóñå
- Èíòåðôåéñ
- Îáùåå êîëè÷åñòâî ïîðòîâ
5
- Óðîâåíü êîììóòàòîðà
L2
- Òèï ðàçúåìà äëÿ "âèòîé ïàðû"
RJ45
- Òåõíîëîãèè
- Ñòàíäàðòû
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX,, IEEE 802.3x for Flow Control
- Óïðàâëåíèå ïîòîêàìè
IEEE 802.3x flow control, back pressure flow control
- Òàáëèöà MAC-àäðåñîâ
2K
- Ðàçìåð áóôåðà ïàêåòîâ
768 Êáèò
- Ïîðòû Fast Ethernet 10/100 Ìáèò/ñ
- Âèòàÿ ïàðà (ðàçúåì RJ45)
4
- Ïîðòû Fast Ethernet 100 Ìáèò/ñ
- Îäíîìîäîâîå îïòîâîëîêíî (ðàçúåì SC)
1
- Õàðàêòåðèñòèêè îïòîâîëîêîííîãî èíòåðôåéñà Fast Ethernet
- Òèï îïòîâîëîêîííîãî êàáåëÿ
9/125 ìêì
- Äàëüíîñòü ïåðåäà÷è ïî îïòîâîëîêíó
äî 40 êì
- Äëèíà âîëíû ïî îïòîâîëîêíó, íì
1310
- Ìîùíîñòü îïòè÷åñêîãî ïåðåäàò÷èêà, äÁì
-5
- ×óâñòâèòåëüíîñòü îïòè÷åñêîãî ïðèåìíèêà, äÁì
-34
- Äîïóñòèìûå ïîòåðè â êàíàëå ñâÿçè, äÁì
29
- Íàñûùåíèå ïðèåìíèêà, äÁì
-3
- Ñâåòîäèîäíûå èíäèêàòîðû
- Ñâåòîäèîäíûå èíäèêàòîðû
Power, 10/100M, 100M
- Óïðàâëåíèå óñòðîéñòâîì
- DIP-ïåðåêëþ÷àòåëè
Çàùèòà îò øèðîêîâåùàòåëüíîãî øòîðìà (âêë/âûêë)
- Òðåáîâàíèÿ ê ýëåêòðîïèòàíèþ
- Ðàáî÷åå íàïðÿæåíèå
12/24/48 Â ïîñò. (9.6 ~ 60 Â ïîñò.)
- Ïîòðåáëåíèå òîêà
0.1 À ïðè 24 Â
- Âîçìîæíîñòü ïîäêëþ÷åíèÿ ðåçåðâíîãî èñòî÷íèêà ýëåêòðîïèòàíèÿ
Åñòü
- Ðàçúåì ýëåêòðîïèòàíèÿ
Êëåììà
- Çàùèòà îò íåâåðíîé ïîëÿðíîñòè
Åñòü
- Óñëîâèÿ ýêñïëóàòàöèè
- Ðàáî÷àÿ òåìïåðàòóðà, °C
-10 ~ +60
- Òåìïåðàòóðà õðàíåíèÿ, °C
-40 ~ +85
- Ðàáî÷àÿ âëàæíîñòü, %
5 ~ 95
- Çàùèòà
- Çàùèòà îò ïûëè è âëàãè
IP30
- Çàùèòà ïî òîêó
1.1 À
- Êîíñòðóêòèâíûå ñâîéñòâà
- Ìàòåðèàë êîðïóñà
Ìåòàëë
- Ðàçìåðû è âåñ
- Ãàáàðèòíûå ðàçìåðû, ìì
30 x 115 x 70
- Âåñ íåòòî, êã
0.18
- Ìîíòàæ
- Ìîíòàæ
Íà DIN-ðåéêó
Íàñòîëüíûé/íàñòåííûé (îïöèîíàëüíî)
- Íàëè÷èå ìåæäóíàðîäíûõ ñåðòèôèêàòîâ
- Áåçîïàñíîñòü
UL508
- Âçðûâîáåçîïàñíîñòü
ATEX Zone 2 Ex nA nC IIC T4 Gc
UL/cUL Class 1 Division 2
- Ýëåêòðîìàãíèòíàÿ ñîâìåñòèìîñòü (EMI)
CISPR 32
FCC Part 15 Subpart B Class A
- Ýëåêòðîìàãíèòíàÿ ñîâìåñòèìîñòü (EMS)
IEC 61000-4-11
IEC 61000-4-2 (ESD)
IEC 61000-4-3 RS
IEC 61000-4-4 (EFT)
IEC 61000-4-5 Surge
IEC 61000-4-6 CS
IEC 61000-4-8
- Ýëåêòðîìàãíèòíàÿ ñîâìåñòèìîñòü (EMC)
EN 55032/24
- Ïðèìåíåíèå â ìîðñêèõ ñèñòåìàõ
ABS
DNV
GL
LR
NK
- Ïðèìåíåíèå íà òðàíñïîðòå
EN 50121-4
NEMA TS2
- Óäàðû
IEC 60068-2-27
- Ñâîáîäíîå ïàäåíèå
IEC 60068-2-32
- Âèáðàöèè
IEC 60068-2-6
- Ñðåäíåå âðåìÿ íàðàáîòêè íà îòêàç (MTBF), ÷àñîâ
3040784
- Ãàðàíòèéíûé ñðîê
- Ãàðàíòèéíûé ñðîê
5 ëåò
- Êîìïëåêò ïîñòàâêè
- Êîìïëåêò ïîñòàâêè
Êðàòêîå ðóêîâîäñòâî ïîëüçîâàòåëÿ
Óñòðîéñòâî